CloudEngine 6800 Series Data Center Switches

CloudEngine 6800 Series Data Center Switches

CloudEngine 6800 series switches are next-generation, high-performance, high-density 10GE/25GE access switches designed for data centers and high-end campus networks. They support 100GE and 200GE uplink ports, offer a variety of rich data center features, and incorporate multiple innovative energy-saving technologies to significantly reduce power consumption.

High reliability

High reliability

M-LAG for millisecond-level link switchover in case of faults.

Intelligence

Intelligence

Significantly simplify operations with intelligent Operations and Maintenance (O&M), proactive reporting of Google Remote Procedure Call (gRPC) high-speed data, proactive detection of network-wide paths, and real-time monitoring of network health status.

Interoperability

Interoperability

Open capabilities allow the switches to interwork with multiple vendors as well as create leading Software-Defined Networking (SDN) networks, evidenced by the Best of ShowNet Award from Interop Tokyo 2016.

Specifications¹


Parameters  CloudEngine 6855-48XS8CQ
Downlink Ports 48 x 10 GE SFP+
Uplink Ports 8 x 40/100 GE QSFP28
Switching Capacity 2.56 Tbit/s
Forwarding Performance 1200 mpps
Reliability LACP
BFD for BGP, IS-IS, OSPF, static route, and VXLAN
Hardware-based BFD
DPFR
MoFRR
O&M Telemetry
Netstream
ERSPAN+
IFIT
Packet Event
Data Center Features 1588v2
MACsec
VXLAN routing and bridging
BGP-EVPN
M-LAG
PFC、AI ECN
Maximum Power Consumption 298 W
Power Supply 600W AC&240V DC
1200W DC
Operating Voltage AC:90V to 290V;HVDC: 190V~290V
DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC
Parameters CloudEngine 6820H-48S6CQ CloudEngine 6820-48S6CQ-A
Downlink Ports 48 x 10 GE SFP+ 48 x 10 GE SFP+
Uplink Ports 6 x 40/100 GE QSFP28 6 x 40/100 GE QSFP28
Switching Capacity 2.16 Tbit/s 2.16 Tbit/s
Forwarding Performance 470 mpps 470 mpps
Buffer 21 MB 21 MB
Reliability LACP
Hardware-based BFD
LACP
Hardware-based BFD
O&M Telemetry
ERSPAN+
Telemetry
ERSPAN+
Data Center Features M-LAG
ECN
M-LAG
ECN
Maximum Power Consumption 282 W 162 W
Power Supply 600W AC&240V DC
1000W -48V DC
1200W HVDC
600W AC&240V DC
1000W DC
1200W HVDC
Operating Voltage AC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~290V
380V HVDC: 190V~400V
AC: 90 V to 290 V
DC: –38.4 V to –72 V
240 V HVDC: 190 V to 400 V
380 V HVDC: 190 V to 400 V

1. This content is applicable only to regions outside the Chinese Mainland. Huawei reserves the right to interpret this content.

Parameters CloudEngine 6870-48S6CQ-EI-A
Downlink Ports 48 x 10 GE SFP+
Uplink Ports 6 x 40/100 GE QSFP28
Switching Capacity 2.16 Tbit/s
Forwarding Performance 720 mpps
Buffer 8 GB
Reliability LACP
BFD for BGP, IS-IS, OSPF, static route, and VXLAN
O&M Telemetry
Netstream
sFlow
ERSPAN
Data Center Features VXLAN routing and bridging
BGP EVPN
M-LAG
DCBX, PFC, and ETS
Maximum Power Consumption 394 W
Power Supply 600W AC&240V DC
1000W -48V DC
1200W HVDC
Operating Voltage AC: 90V~290V
DC: -38.4V~-72V
380V HVDC: 190V~400V

1. This content is applicable only to regions outside the Chinese Mainland. Huawei reserves the right to interpret this content.

Parameters  CloudEngine 6881-48S6CQ CloudEngine 6881-48T6CQ CloudEngine 6881H-48S6CQ CloudEngine 6881H-48T6CQ
Downlink Ports 48 x 10 GE SFP+ 48 x 10 GE Base-T 48 x 10 GE SFP+ 48 x 10 GE Base-T
Uplink Ports 6 x 40/100 GE QSFP28
Switching Capacity 2.16 Tbit/s
Forwarding Performance 940 mpps 954 mpps
Buffer 42 MB
Reliability LACP
BFD for BGP, IS-IS, OSPF, static route, and VXLAN
Microsegmentation
Hardware-based BFD
LACP
Hardware-based BFD
O&M Telemetry
Netstream
sFlow
ERSPAN+
Telemetry
Netstream
ERSPAN+
Data Center Features VXLAN routing and bridging
BGP EVPN
M-LAG
PFC and ECN
VXLAN routing and bridging
BGP-EVPN
M-LAG
PTP
Maximum Power Consumption 349 W 452 W 349 W 452 W
Power Supply 600W AC&240V DC
1000W -48V DC
1200W HVDC
Operating Voltage AC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~290V
380V HVDC: 190V~400V
AC: 90V~290V
DC: -38.4V~-72V
380V HVDC: 190V~400V

1. This content is applicable only to regions outside the Chinese Mainland. Huawei reserves the right to interpret this content.

Parameters  CloudEngine 6885-48YS8CQ CloudEngine 6885-48YS8CQ-T CloudEngine 6885H-48YS8CQ CloudEngine 6885L-48YS8CQ CloudEngine 6885-LL-56F
Downlink Ports 48 x 10/25 GE SFP28 or 48 x 50 GE SFP56 48 x 10/25 GE SFP28 or 48 x 50 GE SFP56 48 x 25GE SFP28/48 x 50GE SFP56 48 x 10/25 GE SFP28 48 x 10/25 GE SFP28
Uplink Ports 8 x 40/100 GE QSFP28 or 8 x 200 GE QSFP56 8 x 40/100 GE QSFP28 or 8 x 200 GE QSFP56 8 x 100GE QSFP28/8 x 200GE QSFP56 8 x 40/100 GE QSFP28
Switching Capacity 8 Tbit/s 8 Tbit/s 8 Tbit/s 4 Tbit/s 2.4 Tbit/s
Forwarding Performance 1200 mpps 1200 mpps 1200 mpps 1200 mpps 1200 mpps
Reliability LACP
BFD for BGP, IS-IS, OSPF, static route, and VXLAN
Hardware-based BFD
DPFR
MoFRR
LACP
BFD for BGP, IS-IS, OSPF, static route, and VXLAN
Hardware-based BFD
DPFR
MoFRR
LACP
BFD for BGP, IS-IS, OSPF, static route, and VXLAN
Hardware-based BFD
DPFR
MoFRR
LACP
BFD for BGP, IS-IS, OSPF, static route, and VXLAN
Hardware-based BFD
DPFR
MoFRR
DPCF
LACP
BFD for BGP, IS-IS, OSPF, static route
MoFRR
O&M Telemetry
Netstream
ERSPAN+
IFIT
Packet Event
Telemetry
Netstream
ERSPAN+
IFIT
Packet Event
Telemetry
Netstream
ERSPAN+
IFIT
Packet Event
Telemetry
Netstream
ERSPAN+
IFIT
Packet Event
Telemetry
Netstream
ERSPAN+
Edge intelligence
Packet Event
Data Center Features 1588v2
MACsec
VXLAN routing and bridging
BGP-EVPN
M-LAG
PFC、AI ECN
TPM
1588v2
MACsec
VXLAN routing and bridging
BGP-EVPN
M-LAG
PFC、AI ECN
1588v2
MACsec
VXLAN routing and bridging
BGP-EVPN
M-LAG
PFC、AI ECN
1588v2
VXLAN routing and bridging
BGP-EVPN
M-LAG
PFC、AI ECN
Minimum L2/L3 forwarding delay: 320 ns to 350 ns
1588v2
M-LAG
PFC、AI ECN
Maximum Power Consumption 326 W 326 W 147 W (100% traffic load, copper cables on 24 x 25G + 4 x 100G ports, normal temperature, dual AC power modules)
166 W (100% traffic load, short-distance optical modules on 24 x 25G + 4 x 100G ports, normal temperature, dual AC power modules)
48x25G+8x100G:
197 W (100% load, all-port short-distance optical modules, normal temperature, dual AC power supplies)
313 W (100% load, full-port long-distance optical module, high temperature, dual AC power supplies)
176 W
Power Supply 600W AC&240V DC
1200W DC
600W AC&240V DC
1200W DC
600 W AC&240 V DC
1200 W DC
600W AC&240V DC
1200W DC
400W DC
600W AC&240V DC
1200W DC
Operating Voltage AC:90V to 290V;HVDC: 190V~290V
DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC
AC:90V to 290V;HVDC: 190V~290V
DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC
AC:90V to 290V;HVDC: 190V~290V
DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC
600 W AC&240 V DC power module: 90 V AC to 290 V AC, 45/65 Hz; 240 V DC
1200 W DC power module: –48 V DC to –60 V DC; +48 V DC
400 W DC power module: –48 V DC to –60 V DC; +48 V DC
AC:90V to 290V;HVDC: 190V~290V
DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC
Parameters CloudEngine 6863-48S6CQ CloudEngine 6863E-48S6CQ CloudEngine 6863H-48S6CQ
Downlink Ports 48 x 10/25 GE SFP28 48 x 10/25 GE SFP28 48 x 10/25 GE SFP28
Uplink Ports 6 x 40/100 GE QSFP28 6 x 40/100 GE QSFP28 6 x 40/100 GE QSFP28
Switching Capacity 3.6 Tbit/s 3.6 Tbit/s 3.6 Tbit/s
Forwarding Performance 940 mpps 940 mpps 954 mpps
Buffer 42 MB 42 MB 42 MB
Reliability LACP
Microsegmentation
Hardware-based BFD
LACP
Microsegmentation
Hardware-based BFD
LACP
Hardware-based BFD
O&M Telemetry
Netstream
sFlow
ERSPAN+
Telemetry
Netstream
sFlow
ERSPAN+
Telemetry
Netstream
ERSPAN+
Data Center Features VXLAN routing and bridging
BGP EVPN
M-LAG
PFC and ECN
VXLAN routing and bridging
BGP EVPN
M-LAG
PFC and ECN
VXLAN routing and bridging
BGP-EVPN
M-LAG
PTP
Maximum Power Consumption 349 W 384 W 384 W
Power Supply 600W AC&240V DC
1000W -48V DC
1200W HVDC
600W AC&240V DC
1000W -48V DC
1200W HVDC
600W AC&240V DC
1000W -48V DC
1200W HVDC
Operating Voltage AC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~290V
380V HVDC: 190V~400V
AC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~290V
380V HVDC: 190V~400V
AC: 90V~290V
DC: -38.4V~-72V
380V HVDC: 190V~400V

1. This content is applicable only to regions outside the Chinese Mainland. Huawei reserves the right to interpret this content.

Parameters CloudEngine 6860-HAM CloudEngine 6866-48S8CQ-P
Downlink Ports 48 x 10/25 GE SFP28 or 48 x 50 GE SFP56 48 x 10/25 GE SFP28 or 48 x 50 GE SFP56
Uplink Ports 8 x 40/100 GE QSFP28 or 8 x 200 GE QSFP56 8 x 40/100 GE QSFP28 or 8 x 200 GE QSFP56
Switching Capacity 8 Tbit/s 8 Tbit/s
Forwarding Performance 2175 mpps 2175 mpps
Buffer 64 MB 64 MB
Reliability LACP
Hardware-based BFD
LACP
Hardware-based BFD
O&M Telemetry
Netstream
ERSPAN+
AnyFlow
Intelligent Traffic Analysis
Packet Event
Telemetry
Netstream
ERSPAN+
AnyFlow
Intelligent Traffic Analysis
Packet Event
Data Center Features 32k multicast entries, MoFRR
VXLAN routing and bridging
BGP EVPN
M-LAG 3.0
VXLAN routing and bridging
BGP EVPN
M-LAG
Intelligent and Lossless Network AI ECN
PFC Deadlock Prevention
ECN Overlay
iQCN
Maximum Power Consumption 48 x 50 GE + 8 x 200 GE: 619 W
48 x 25 GE + 8 x 100 GE: 544 W
48 x 50 GE + 8 x 200 GE: 619 W
48 x 25 GE + 8 x 100 GE: 544 W
Power Supply 600W AC&240V DC
1000W -48V DC
1200W HVDC
600W AC&240V DC
1000W -48V DC
1200W HVDC
Operating Voltage AC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~290V
380V HVDC: 190V~400V
AC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~290V
380V HVDC: 190V~400V

1. This content is applicable only to regions outside Chinese Mainland. Huawei reserves the right to interpret this content.

TOP